An accurate, infection-free spirometer that connects to the Bionet Cardio7 machines to provide two-in-one diagnostic testing. This spirometer uses a disposable sensor, making it easy to maintain because the sensor does not need to be disinfected between uses.



By adding the SPM-300 to your current Cardio7, you can test FVC, SVC, MVV and perform a pre-post Bronchodilator comparison. Real-time volume-flow and time-flow monitoring is provided on the color LCD display. 120 tests are stored and a full size printout is provided for easy charting.



Features and Benefits

  • Spirometry readouts displayed on ECG monitor (touchscreen monitor with cardio7).
  • Low maintenance cost – uses ecg machine and its A4-size chart paper for printing.
  • Printouts include detailed reference graph.
  • Disposable mouthpieces minimize cleaning and sterilization.
  • Memory storage: 120 cases of built-in data.
  • Ni-MH rechargeable battery allows cordless use for up to 1 hours (approx. 100 printouts)
  • Compatible with PACS & EMR with BMS PLUS program system (Optional)

Tests/Measurements

  • FVC (Forced Vital Capacity)
  • SVC (Slow Vital Capacity)
  • MVV (Maximum voluntary ventilation)
  • PRE-POST bronchodilator comparison
  • Morris/Polgar, Knudson/ITS, ECCS/Quanjer




Materials Included

  • SPM-300 Spirometer
  • Sensor
  • Handle Dock
  • Nose Clip
  • Diagnosis Guide
  • Operation Manual
  • 100 Mouthpieces


Technical Specifications

  • Dimensions: 47 (W) x 200 (H) x 34 (D) mm
  • Weight: 250 g
  • Measuring Values:
    • FVC: FVC, FEV 1.0, FEV 1/FVC, FEF 0.2 – 1.2L, FEF 25 – 75%, FEF 75 – 85%, PEF, FEF 25%, FEF 50%, FEF 75%, FIVC, FEV6, PEFT, FET 100%
    • SVC: SVC, ERV, IRV, TV, EC
    • MVV: MVV, FB, TV
  • Presentation
    • Flow volume loop
    • MVV: MVV, FB, TV
    • Measurement values table
  • Measuring Range
    • Flow: 0 to ± 14 L/s
    • Volume: 0 to ± 12 L
  • Measuring Method: Differential pressure method
  • Prediction Equation: Morris-Polgar, ECCS-Quanjer, Knudson-ITS, Pereira, Korea CJK
  • Sample Rate: 200 samples/sec
  • Flow Impedance: &lt, 0.2 mbar s/l at 12 l/s
  • Measuring Accuracy: Complies with ATS (American Thoracic Society)
  • Environment
    • Ambient temperature: 15 to 40°C (59 to 104°F)
    • Relative humidity: 10 to 90% (non-condensing)
    • Atmospheric pressure: 700 to 1060 hPa