The ECG E80 is a simple, intuitive operation with touch-enabled device.
Features and Benefits
- 12 inch color LCD Touch Screen with intuitionistic display
- Displays 12 waveforms synchronously
- Ease to use intuitive QWERTY keyboard design with multi-function shortcut key
- Waterproof keyboard design
- Portable, overturning and folding design.
- Support saving to Internal data, SD card and USB flash disk
- Support transferring data, reviewing data and reanalyzing data
- High-capacity data saving into built-in
- Innovative digital filters for better performance
- Fast-speed baseline correction algorithm
- 24-bit high-resolution & 1000Hz high- frequency data sampling
- 24-bit high-accuracy data saving ensures accuracy of follow-up data analysis
Materials Included
- E80 ECG Unit
- 10 Lead ECG Patient Cable
- (100) Electrodes
- (10) Alligator Clips
- (1) 11.1V/4000mAH Lithium Battery
- User Manual
Technical Specifications
- Dimensions: 12′ x 8′ x 6′
- Unit Weight: 15 lbs
- Display: 12′ TFT LCD
- Resolution: 800 x 600 pixels
- Power Supply:
- Input Voltage: AC: 100V~240V, 50Hz/60Hz
- Input Power: 60VA
- Environment Specifications:
- Operation
- Environment Temperature: +5°C ~ +40°C
- Relative Humidity: 25% ~ 93%
- Atmospheric Pressure: 700hPa ~ 1060hPa
- Operation
- Storage:
- Internal Memory: 100 Groups ECG Data
- External Memory: SD Card or USB
- Storage Mode: Background Storage Automatically
- Storage Format: XML
- Input/Output:
- Keyboard: Standard PC104 (Position)
- Touchscreen: Option
- Network: 1 x RJ-45 Socket
- USB Connector: 2 x USB Host (Support Hot-Swap)
- SD Card: 1 x Standard SD Card Socket
- Record:
- Recording Way: Thermal Dot Array
- Horizontal Resolution: 40 Dots/mm
- Vertical Resolution: 8 Dots/mm
- Recording Speed: 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- Error: ±3%
- Recording Linearity: 0.5 mm/30M
- Paper Length: 295 mm / 280 mm
- Paper Width: 210 mm / 216 mm
- Paper Type: Z-Fold
- Accuracy:
- ± 5% (X Axis)
- ± 5% (Y Axis)
- Record Type: More than 10 kind of printing methods
- Measure and Diagnosis of ECG:
- HR Range: 30 bpm – 350 bpm
- HR Precision: ±1bpm (10s average)
- Coefficient Error: 5%, 0.333
- Measure Inform of ECG waveform:
- P Time Limit
- PR Interphase
- QRS Time Limit
- QT Interphase
- RR Interphase
- Rv5 Swing
- Sv1 Swing
- Rv6 Swing
- Sv2 Swing
- Rv5+Swing
- P Axis
- QRS Axix
- Diagnosis Analyze: 140 Kinds
- Display of ECG Collection:
- Signal Input: 12-Lead, Defibrillator-proof, Pacemaker Pulse Rejection
- Degree of Protection Against Electric Shock: 4000V, Type CF Applied Part
- Polarization Voltage Resistance: ± 500mV
- Response to Frequency: 0.05Hz-150Hz (-3dB)
- Baseline Filter: 0.05 Hz, 0.15Hz, 0.25Hz, 0.5Hz
- ECG Filter: 25Hz, 35Hz, 45Hz,
- Low Pass Filter: 75Hz, 100Hz, 150Hz
- Gain Selection: 2.5, 5, 10, 20, 10/5, ACG (mm/mV)
- Gain Accuracy: ±5%
- Time Base Selection: 5 mm/s, 6.25 mm/s, 10 mm/s, 12,5 mm/s, 25 mm/s, 50 mm/s
- Input Impedance: 50 M
- Current of Input Loop: 50 n A
- Patient Leak Current: 10µA
- CMRR: 109dB (with AC Filter)
- Time of response to wave displaying: 5s
- Time of baseline recovered after switching leads: 1s
- Defibrillator-Proof: 5000v 360J
- Recovering Time for Defibrillator-Proof: 5s
- Recovering Time for Defribrillator Electrode Polarization: 10s
- Energy Reduced: 10%
- Voltage Transfer: 1 V
Warranty Information
- 18-Month Warranty