Roll over image to zoom in
The CLEO Capnography monitor is an intuitive approach to patient End-Tidal CO2 measurement.
Features and Benefits
- 5′ Touch Screen making the CLEO easy and intuitive for any user
- Portable and light weight design
- Long life lithium ion battery
- Suited for bedside and mobile spot check use.
- Respiration and pleth waveform
- The CO2 uses a 50/ml per minute sidestream method to deliver the most accurate EtCO2 readings
- Used on both intubated and non-intubated patients
- The sample line connection system uses filter cells to eliminate the potential of cross contamination
- Optional NIBP and SpO2 available
Note: The CLEO Data Manager Software is available to download.
Materials Included
- CLEO Pulse Oximeter
- (1) Sample Line
- (1) Power Cord
- (1) Adult Blood Pressure Cuff (Optional)
- (1) Blood Pressure Hose (Optional)
- (1) Adult Finger Sensor (Optional)
- (1) Sensor Cable (Optional)
- User Manual
Technical Specifications
- Application: Neonatal, Pediatric and Adult Patients
- Weight: 2.5 lbs
- Dimensions
- Height: 8′
- Width: 4.5′
- Depth: 4′
- Display: 5.0′ Diagonal Color TFT
- Resolution: 800 x 3 (RGB) x 480
- Indicator:
- Alarm Indicator
- Power Indicator
- Pulse Beep and Alarm Sound
- Trend Time: 1 to 72 hours
- EtCO2
- Mode of Sampling: Sidestream or Mainstream
- Principle or Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts.
- CO2 Measuring Range: 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
- CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated
- CO2 Resolution:
- 0.1 mmHg (0-69 mmHg)
- 0.25 mmHg (70-150 mmHg)
- CO2 Accuracy:
- 0-40 mmHg ± 2 mmHg
- 41-70 mmHg ± 5% of Reading
- 71-100 mmHg ± 8% of Reading
- 101-150 mmHg ± 10% of Reading
- Above 80 breath per minute ± 12% of Reading
- Sampling Rate: 100Hz
- Respiration Rate: 1-150 bpm
- Respiration Rate Accuracy: ± 1 Breath
- Response Time: <, 3 seconds includes transport time and rise time
- Inspired CO2 measurement range: 3 – 50 mmg
- Standards: Meets performance standards of ISD/FDIS: 2157:2003 (E) ASTM F1456-01, IEC/COV 60601-2-55
- SpO2 (Optional)
- ASpO2: Anti-Motion SpO2
- SpO2 Range: 0 – 100%
- SpO2 Accuracy:
- ± 2% (70 – 100% non-motion)
- ± 3% (70 – 100% motion)
- Pulse Rate Range: 30 – 250 bpm
- Pulse Rate Accuracy:
- ± 2 bpm (non-motion)
- ± 3 bpm (motion)
- Alarm Upper-Lower Limit:
- Upper Limit: 70 – 100%
- Lower Limit: 70 – 100%
- SpO2 Probe:
- Red Light LED Wavelength:
- 660nm ± 5nm
- Infrared Light LED Wavelength: 940 ± 5nm
- Standard: Meets performance standards of EN ISO 9919:2005
- Red Light LED Wavelength:
- NIBP (Optional)
- Measuring Technology: Automatic Oscillating Measuring
- Cuff Inflating: <, 30s (0~300 mmH, standard adult cuff)
- Measuring Period: AVE <,40s
- Mode: Manual, Auto, STAT
- Measuring Interval in AUTO mode: 2 min – 4 hours
- Pulse Rate Range: 30 bpm – 250 bpm
- Measuring Range:
- Adult/Pediatric Mode
- SYS: 40 – 250 (mmHg)
- DIA: 15 – 200 (mmHg)
- Neonatal Mode
- SYS: 40 – 135 (mmHg)
- DIA: 15 – 100 (mmHg)
- Resolution: 1 mmHg
- Pressure Accuracy: Maximum Mean Error ± 5 mmHg
- Maximum Standard Deviation: 8 mmHg
- Overpressure Protection:
- Adult Mode/Pediatric: 280 (mmHg)
- Neonatal: 150 (mmHg)
- Alarm Limit:
- SYS: 50 – 240 mmHg
- DIA: 15 – 180 mmHg
- Standards: Meets performance standards of ANSI/AAMI SP10:2002
- Adult/Pediatric Mode
- Networking
- Wired Networking:
- Industry Standard: 802.1 b/g wired network
- Frequency Range: 2.412 – 2.484 GHz
- Connected Bedside Number: Up to 16 bedside monitors
- Wireless Networking
- Up to 100m indoors
- Industry Standard 802.11 b/g wireless
- Supports TCP/IP and UDP/IP Protocols
- Wired Networking:
- Power
- Source: External AC Power or Internal Battery
- AC Power: 100 – 240 VAC, 50/60 Hz, 150VA
- Battery: Built-in and Lithium Ion Recharge, 12.6v/5Ah
- Charge Time: 8 Hours
- Operating Time: 3 Hours
- Fuse: 3.15A/250V
- Environmental Specifications
- Temperature
- Operating: 5 – 40 °C
- Storage: -10 – 45 °C
- Humidity Range:
- Operating: 80 %
- Storage: 80 %
- Temperature
- LCD Specifications
- Display Type: TFT
- Size: 5′ Inch Diagonal
- Active Area: 152.4 (W) x 91.44 (H) mm
- Dot Pitch: 0.0635 (W) x 0.1905 (H) mm
- Display Mode: Normally, white, transmissive
- Interface: Digital (TTL)
- Surface Treatment: Anti-Glare
- Touchscreen
- Type: Four-Wire Analog Resistive Touch Panel
- Input Mode: Stylus Pen or finger
- Connector: FPC
- Voltage: 7VDC
- Chattering: 10ms
- Transparency: 80%
- Surface Hardness: 3H
- Durability-Surface Scratching: Write 100,000
- Active Force: 80 gf
- Knock Test: 1,000,000 times
Warranty Information
- 2-Year Warranty