The CLEO vital signs monitor is an intuitive approach to patient vital signs measurement.
Features and Benefits
- 5′ Touch Screen making the CLEO easy and intuitive for any user
- Portable and light weight design
- Long life lithium ion battery
- Suited for bedside and mobile spot check use.
- Respiration and pleth waveform
- Comes with standard NIBP and SpO2 measurements
- Optional Covidien Filac 3000™ Thermometer (Thermometer does not interface with the CLEO Monitors, readings are separate)
- 4 Second oral temperature reading brightly displayed on-screen.
- Supports infection control by utilizing single use probe covers and probe isolation chamber
Note: The CLEO Data Manager Software is available to download.
Materials Included
- CLEO Vital Signs Monitor
- (1) Adult Blood Pressure Cuff
- (1) Blood Pressure Hose
- (1) Adult Finger Sensor
- (1) Sensor Cable
- (1) Power Cord
- (1) Filac Thermometer (Optional)
- 4 ft Oral Probe (Optional)
- 1 Probe Cover (Optional)
- User Manual
Technical Specifications
- Application: Neonatal, Pediatric and Adult Patients
- Dimensions
- Height: 8′
- Width: 4.5′
- Depth: 4′
- Weight: 2.5 lbs
- Display: 5.0′ Diagonal Color TFT
- Resolution: 800 x 3 (RGB) x 480
- Indicator:
- Alarm Indicator
- Power Indicator
- Pulse Beep and Alarm Sound
- Trend Time: 1 to 72 hours
- NIBP
- Measuring Technology: Automatic Oscillating Measuring
- Cuff Inflating: <, 30s (0~300 mmH, standard adult cuff)
- Measuring Period: AVE <,40s
- Mode: Manual, Auto, STAT
- Measuring Interval in AUTO mode: 2 min – 4 hours
- Pulse Rate Range: 30 bpm – 250 bpm
- Measuring Range:
- Adult/Pediatric Mode
- SYS: 40 – 250 (mmHg)
- DIA: 15 – 200 (mmHg)
- Neonatal Mode
- SYS: 40 – 135 (mmHg)
- DIA: 15 – 100 (mmHg)
- Resolution: 1 mmHg
- Pressure Accuracy: Maximum Mean Error ± 5 mmHg
- Maximum Standard Deviation: 8 mmHg
- Overpressure Protection:
- Adult Mode/Pediatric: 280 (mmHg)
- Neonatal: 150 (mmHg)
- Alarm Limit:
- SYS: 50 – 240 mmHg
- DIA: 15 – 180 mmHg
- Standards: Meets performance standards of ANSI/AAMI SP10:2002
- Adult/Pediatric Mode
- SpO2
- ASpO2: Anti-Motion SpO2
- SpO2 Range: 0 – 100%
- SpO2 Accuracy:
- ± 2% (70 – 100% non-motion)
- ± 3% (70 – 100% motion)
- Pulse Rate Range: 30 – 250 bpm
- Pulse Rate Accuracy:
- ± 2 bpm (non-motion)
- ± 3 bpm (motion)
- Alarm Upper-Lower Limit:
- Upper Limit: 70 – 100%
- Lower Limit: 70 – 100%
- SpO2 Probe:
- Red Light LED Wavelength:
- 660nm ± 5nm
- Infrared Light LED Wavelength: 940 ± 5nm
- Standard: Meets performance standards of EN ISO 9919:2005
- Red Light LED Wavelength:
- Rapid Temperature (Optional)
- Temperature Measurement Range: 30°C to 43°C (86°F to 109°F)
- Typical Measurement:
- Oral (Quick Mode): 3-5 Seconds (non-fever temps), 8-10 seconds (fever temps)
- Oral (Standard Mode): 6-10 seconds
- Axillary Mode: 8-12
- Rectal Mode: 10-14 seconds
- Direct Mode (All Sites): 60-120 seconds
- Pulse Timer: 60 second count with a ‘beep’ at 15 seconds, 2 ‘beeps’ at 30 seconds, 1 ‘beep’ at 45 seconds and 2 ‘beeps’ at 60 seconds.
- Patient Accuracy: A standard Prediction Mode reading and a Direct Mode reading will differ by less than ± 0.2°C (± 0.4 °F) on 98% of tested patients
- Batteries: Four AA Required. Standard IEC package size. Alkaline – 1.5 Volt
- Standards: Meets performance standards of EN 12470-3:2000, ASTM E1112:2006
- Networking
- Wired Networking:
- Industry Standard: 802.1 b/g wired network
- Frequency Range: 2.412 – 2.484 GHz
- Connected Bedside Number: Up to 16 bedside monitors
- Wireless Networking
- Up to 100m indoors
- Industry Standard 802.11 b/g wireless
- Supports TCP/IP and UDP/IP Protocols
- Wired Networking:
- Power
- Source: External AC Power or Internal Battery
- AC Power: 100 – 240 VAC, 50/60 Hz, 150VA
- Battery: Built-in and Lithium Ion Recharge, 12.6v/5Ah
- Charge Time: 8 Hours
- Operating Time: 3 Hours
- Fuse: 3.15A/250V
- Environmental Specifications
- Temperature
- Operating: 5 – 40 °C
- Storage: -10 – 45 °C
- Humidity Range:
- Operating: 80 %
- Storage: 80 %
- Temperature
- LCD Specifications
- Display Type: TFT
- Size: 5′ Inch Diagonal
- Active Area: 152.4 (W) x 91.44 (H) mm
- Dot Pitch: 0.0635 (W) x 0.1905 (H) mm
- Display Mode: Normally, white, transmissive
- Interface: Digital (TTL)
- Surface Treatment: Anti-Glare
- Touchscreen
- Type: Four-Wire Analog Resistive Touch Panel
- Input Mode: Stylus Pen or finger
- Connector: FPC
- Voltage: 7VDC
- Chattering: 10ms
- Transparency: 80%
- Surface Hardness: 3H
- Durability-Surface Scratching: Write 100,000
- Active Force: 80 gf
- Knock Test: 1,000,000 times
Warranty Information
- 2-Year Warranty