Roll over image to zoom in
The Omni Express patient monitor is a good choice for health care professionals who require precision, performance, and affordability.
Features and Benefits
- High resolution 7 inch touch screen to optimize the speed of patient care
- 72 hour graphic and tabular trending
- Large, easy to read fonts
- Rigid, high quality construction
- Wireless network compatibility
- Four hour backup battery
- Pre-configured with non-invasive blood pressure, 3/5 ECG with arrhythmia detection, SpO2, and temperature and respiration.
- Optional components available
- Sidestream CO2
- Mainstream CO2
- Embedded Thermal Printer
Materials Included
- Omni Multi-parameter Patient Monitor
- (1) 3 Lead ECG Cable
- (1) Adult Blood Pressure Monitor
- (1) Blood Pressure Cuff Hose
- (1) Adult Finger Sensor
- (1) 4 Pin Skin Surface Temperature Probe
- (1) Sensor Cable
- User Manual
Technical Specifications
- Performance Specifications
- Display: 7′ Color TFT
- T Resolution: 1024Ч860
- Trace: 2 or 3 waveforms
- Waveforms: ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, ETCO2)
- Indicator:
- Alarm indicator
- Power indicator
- QRS beep and alarm sound
- Trend Time: From 30 minutes to 72 hours
- ECG
- Input: 3 lead ECG cable and standard AAMI line for connection
- Lead Choice: I, II, III, aVR, aVF, aVL, V
- Gain Choice: Ч0.5, Ч1.0, Ч2.0
- CMRR (common mode rejection ratio): >,100 dB at 50 Hz or 60 Hz
- Frequency Characteristic: 0.67~40 Hz (+3 dB attenuation)
- ECG Waveforms: 7 channels
- Sweep Speed: 12.5, 25 and 50 mm/s
- HR Display Range: 30~300 bpm
- Accuracy: ±1 bpm or ±1%, whichever is greater
- Alarm Limit Range
- Upper Limit: 80~400 bpm
- Lower Limit: 20~150 bpm
- Respiration
- Measure Method: RA-LL impedance
- Range: 0 ~ 120 rpm
- Accuracy: ± 3 rpm
- Alarm Upper-lower Limit:
- Upper Limit: 6 ~ 120 rpm
- Lower Limit: 3 ~ 120 rpm
- Sweep Speed: 12.5 and 25mm/s
- NIBP
- Measuring Technology: Automatic oscillating measurement
- Cuff Inflating: <, 30s (0~300 mmHg, standard adult cuff)
- Measuring Period: AVE <, 40s
- Mode: Manual, Auto, STAT
- Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
- Pulse Rate Range: 30 bpm ~ 250 bpm
- Measuring Range:
- Adult/Pediatric Mode
- SYS 40~250 (mmHg)
- DIA 15!200 (mmHg)
- Neonatal Mode
- SYS 40!135 (mmHg)
- DIA 15!100 (mmHg)
- Adult/Pediatric Mode
- Resolution: 1mmHg
- Pressure Accuracy:
- Maximum Mean Error: ± 5mmHg
- Maximum Standard Deviation: 8mmHg
- Overpressure Protection:
- Adult Mode: 280 (mmHg)
- Neonatal Mode: 150 (mmHg)
- Alarm Limit:
- SYS 50~240 mmHg
- DIA 15~180 mmHg
- Temperature
- Range: 25~50 (єC)
- Accuracy:
- ± 0.2 єC (25.0~34.9 єC)
- ± 0.1 єC (35.0~39.9 єC)
- ± 0.2 єC (40.0~44.9 єC)
- ± 0.3 єC (45.0~50.0 єC)
- Display Resolution: 0.1 єC
- Alarm Upper-lower Limit:
- Upper limit 0~50 єC
- Lower limit 0~50 єC
- Channel: 1 channels
- Alarm Limit: 10~50 (єC)
- SpO2
- Measurement Range: 0% to 100%
- Resolution Accuracy: 1%
- Accuracy:
- 70% to 100%, +/-2%, Adult/Pediatric, Non-motion conditions 70% to 100%, +/-3%, Neonate, Non-motion conditions
- 70% to 100%, +/-3%, Adult/Pediatric/Infant/Neonate, Motion conditions
- 70% to 100%, +/-2%, Adult/Pediatric/Infant/Neonate, Low perfusion conditions
- Average Time: 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec (user selectable)
- Sensitivity Settings: Normal, Maximum, APOD (user selectable)
- Pulse Rate:
- Measurement Range: 25 to 240 bpm
- Accuracy:
- +/-3 bpm, Adult/Pediatric/Infant/ Neonate, Non-motion conditions
- 5 bpm, Adult/Pediatric/Infant/ Neonate, motion conditions
- Resolution: 1 bpm
- Accuracy:
- Measurement Range: 25 to 240 bpm
- Perfusion Index: Measurement range: 0.02 – 20%
- EtCO2 (Optional)
- Mode of Sampling: Sidestream or Mainstream
- Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
- CO2 Measurement Range: 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
- CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)
- CO2 Resolution: 0.1mmHg (0-69mmHg), 0.25mmHg (70-150mmHg)
- CO2 Accuracy:
- 0~40 mmHg ± 2 mmHg
- 41~70 mmHg ± 5% of reading
- 71~100 mmHg ± 8% of reading
- 101~150 mmHg ± 10% of reading
- Above 80 breath per minute ± 12% of reading
- Sampling Rate: 100 Hz
- Respiration Rate: 2 ~ 150 bpm
- Respiration Rate Accuracy: ±1 breath
- Response Time: <, 3 seconds – includes transport time and rise time
- Inspired CO2 Measurement Range: 3 ~ 50 mmHg
- Networking
- Wired Networking:
- Industry standard: IEEE 802.3 wired network
- Connected bedside number: Up to 16 bedside monitors
- Up to 16 bedside monitors: RJ45 interface or RS232 serial port
- Wireless Networking
- Up to 100 m indoors
- Frequency Range: 2.412~2.484 GHz
- Industry standard 802.11b/g wireless
- Supports TCP/IP and UDP/IP Protocols
- Wired Networking:
- Power:
- Source: External AC power and internal battery
- AC Power: 100~240VAC, 50/60Hz, 150VA
- Battery:
- Rechargeable Lead-Acid
- Type: FB 1223 12v-2.3Ah
- Operating time under the normal condition: 1 hour
- Operating time after the first alarm of low battery: 10 minutes
- Charge Time: 4 hours
- Operating Time: 1 hour
- Fuse: T 3.0A
- Environmental Specifications
- Temperature:
- Operating: 5~40 °C
- Storage: -10~45 °C
- Humidity Range
- Operating: 80 %
- Storage: 80 %
- Temperature:
Warranty Information
- 2-Year Warranty