Designed for a fast paced work environment, the Infinium Omni™ patient monitor offers an extremely simple and adaptable user interface.
Features and Benefits
- High resolution 10.1 inch touch screen to optimize the speed of patient care
- 72 hour graphic and tabular trending
- Large, easy to read fonts
- Rigid, high quality construction
- Wireless network compatibility
- Four hour backup battery
- Pre-configured with non-invasive blood pressure, 3/5 ECG with arrhythmia detection, SpO2, and temperature, respiration, OxyCrg, Drug dose calculations
- Optional components available
- Sidestream CO2
- Mainstream CO2
- Cardiac Output Invasive Blood Pressure – Includes 2 IBP cables and a password to open the IBP function
- Embedded Thermal Printer
Materials Included
- Omni Multi-parameter Patient Monitor
- (1) 3 Lead ECG Cable
- (1) Adult Blood Pressure Monitor
- (1) Blood Pressure Cuff Hose
- (1) Adult Finger Sensor
- (1) 4 Pin Skin Surface Temperature Probe
- (1) Sensor Cable
- User Manual
Technical Specifications
- Application: Neonatal, Pediatric and Adult Patients
- Dimensions
- Length: 11′
- Width: 12′
- Height: 6′
- Performance Specifications
- Display: 10.5 inch color touch screen
- Trace: 8 waveforms
- Indicator:
- Alarm indicator
- Power indicator
- QRS beep and alarm sound
- Trend time: 1 – 72 hour
- Recorder:
- Built-in, thermal array, 3 channels
- Record width: 48mm
- Recorder paper: 50mm
- Record speed: 25mm/s, 50mm/s
- ECG
- Input: 3-lead ECG cable and standard AAMI line for connection
- Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
- Gain Choice: x0.5, x1, x2, x4
- Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
- Penetration Voltage: 4000VAC 50/60Hz
- Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
- ECG Waveforms: 3 Channels
- HR Display Range: 30 ~ 300bpm
- Accuracy: ± 1bpm or ±1%, whichever is greater
- Alarm Limit Range Setting:
- Upper Limit: 100 ~ 200bpm
- Lower Limit: 30 ~ 100bpm
- Respiration
- Measure Method: RA-LL impedance
- Range: 0 ~ 120 rpm
- Accuracy: ±3 rpm
- Alarm Limit Setting:
- Upper Limit: 6 ~ 120 rpm
- Lower Limit: 3 ~ 120 rpm
- Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
- NIBP
- Measuring Technology: automatic oscillating measurement
- Cuff Inflating: <, 30s (0 ~ 300 mmHg, standard adult cuff)
- Measuring Period: AVE <, 40s
- Mode: Manual, Auto
- AUTO Mode: 2 min ~ 4 hrs
- Pulse Rate Range: 30 ~ 250 (bpm)
- Measuring Range:
- Adult/Pediatric Mode:
- SYS: 40 ~ 250 (mmHg)
- DIA: 15 ~ 200 (mmHg)
- Neonatal Mode:
- SYS: 40 ~ 135 (mmHg)
- DIA: 15 ~ 100 (mmHg)
- Adult/Pediatric Mode:
- Accuracy:
- Maximum Mean Error: ±5 mmHg
- Maximum Standard Deviation: 8mmHg
- Resolution: 1 mmHg
- Overpressure Protection:
- Adult Mode: 300 (mmHg)
- Neonatal Mode: 160 (mmHg)
- Alarm Limit Setting:
- SYS: 50 ~ 240 mmHg
- DIA: 15 ~ 180 mmHg
- Temperature
- Range: 25 ~ 50 (°C)
- Accuracy:
- ± 0.2°C (25.0 ~ 34.9°C)
- ± 0.1°C (35.0 ~ 39.9°C)
- ± 0.2°C (40.0 ~ 44.9°C)
- ± 0.3°C (45.0 ~ 50.0°C)
- Display Resolution: 0.1°C
- Alarm Limit Setting:
- Upper Limit: 0 ~ 50°C
- Lower Limit: 0 ~ 50°C
- Channel: 2 Channels
- SpO2
- ASpO2: Anti-motion SpO2
- SpO2% Range: 0-100%
- SpO2 Accuracy:
- ± 2% (70 ~ 100%, non-motion)
- ± 3% (70 ~ 100%, motion)
- Pulse Rate Range: 30-250 bpm
- Pulse Rate Accuracy:
- ± 2 bpm (non-motion)
- ± 3 bpm (motion)
- Alarm Limit Setting:
- Upper Limit 70 ~ 100%
- Lower Limit 70 ~ 100%
- SpO2:
- Red light LED wavelength
- 660nm ± 5nm
- Infrared light LED wavelength
- 940nm ± 10nm
- IBP (Optional)
- Measurement Range: -50 ~ 300mmHg
- Channel: 2 channels
- Pressure Transducer: Sensitivity, 5V/V/mmHg
- Impedance Range: 300 ~ 3000
- Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
- Unit: mmHg/kPa selectable
- Resolution: 1mmHg
- Accurancy: ±1mmHg or ±2%, whichever is greater
- Alarm Range: -10 ~ 300mmHg
- IBP (Optional)
- Measurement Range: -50 ~ 300mmHg
- Channel: 2 channels
- Pressure Transducer: Sensitivity, 5V/V/mmHg
- EtCO2 (Optional)
- CO2 Measurement Range: 0 ~ 99mmHg
- Accuracy:
- ± 2mmHg (0 ~ 38mmHg)
- 39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)
- Sampling Rate: 50 ml/min
- Initialization Time: 30 seconds (typical), reaches ±5% steady-state accuracy within 3 minutes.
- Respiration Rate: 0 ~ 150 breaths/min
- Mode: Adult, Neonate
- Networking: Industry standard 802.11b/g wireless network
- Power:
- Source: External AC power or internal battery
- AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
- Battery: Built-in & rechargeable lithium ion
- Operating Time: 3+ hours
- Environmental Specifications
- Temperature:
- Operating: 5 ~ 40 °C
- Storage: -20 ~ 65 °C
- Humidity Range:
- Operating: 80 %
- Storage: 80 %
- Temperature:
Warranty Information
- 2-Year Warranty