- 8.4’’ High-resolution LED display with 8 waveforms
- Portable, less than 3.2 kg
- Easy to use for intuitive operation
- Plug-and-play modular design, more choices for clinical use
- No-fan design for a quiet care environment
- Trust for veterinary use, parameters including ECG, RESP, SpO2 , NIBP, PR, TEMP, IBP, 2 CO , Multi-gas
- Standard features include Nellcor or Masimo SpO2, ST and Arrhythmia, IBP, Temperature and recorder
- 360-degree visible alarm indicator
- 120 hours trend and 48 hours waveforms reviewing
- Available with Sidestream CO2 or Mainstream CO2
Materials Included
- iMEC 8Vet Unit
- (1) Thermal Roll Paper
- (1) Power Cord
- (1) ECG trunk cable, 3/5 lead, adult/pediatric, 12 Pin, defib-proof, AHA/IEC
- (1) ECG leadwires, 3 lead, pinch/clip, adult/pediatric, TPU, AHA, 40′ (101.6cm)
- (5) Alligator Clips
- (1) Masimo or Nellcor SpO2 Cable
- (1) Masimo or Nellcor SpO2 Veterinary Sensor
- (1) 3m NIBP Hose with Connectors
- (1) NIBP Cuff, 5.8 to 10.9 cm
- (1) IBP cable adapter (12 pin to 6 pin)
- (1) MR403B reusable temperature probe, adult, skin, 2 pin
- (1) Lithium Ion Battery
- Mainstream CO2 Kit (for Mainstream CO2 Option)
- Sidestream CO2 Kit (for Sidestream CO2 Option)
Technical Specifications
- Dimensions: 8′ x 11′ x 112′
- Wave Forms: Up tp 8 traces
- ECG: 5 or 3 lead: I, II, III, aVR, aVL, aVF, V
- Respiration: RA-LA/RA-LL Impedance
- SpO2: Nellcor Oximax
- NIBP: Manual, Auto, STAT
- Temperature: 2 Channels
- Invasive Blood Pressure: 2 Channels
- C.O.: No
- EtCO2: Sidestream CO2 or Mainstream CO2
- Multi-Gas: No
- Recorder: 3-trace thermalarray, 50mm
- Reviewing:
- 120 hours trends
- 100 alarm events and associated waveforms
- 1000 groups NIBP
- Up to 48 hours waveforms
- Download to PC: USB stick
- Video Output: Yes, 1 VGA
- Wired Network: Yes, 1 RJ45
- Wireless: Yes Wi-Fi Compatible
ECG Specifications
- RR Range: 15 – 350 bpm ECG
- Gain: 1.25/2.5/5/10/20/40 mm/mV, Auto
- Sweep Speed: 6.25/12.5/25/50 mm/s
- Mode: Diagnostic, Monitor, or Surgical
NIBP Specifications
- Range:
- Systolic: 40 to 270 mmHg
- Diastolic: 10 to 210 mmHg
- Mean: 20 to 230 mmHg
- Interval in Auto Mode: 1/2/2.5/3/5/10/15/20/30/60/90/120/180/240/ 480min
- Max Time Allowed: 180 s
SpO2
- SpO2 Range: 0 – 100%
- Accuracy: 70 to 100%, ±3%
PR
- Range
- 20 to 300 bpm (Nellcor SpO )
- 25 to 350 bpm (IBP)
- 40 to 240 bpm (NIBP)
Respiration
- Lead: I, II or Auto
- RR Range: 0 to 150 rpm
- Accuracy: 7 to 150 rpm: ±2 rpm or ±2%, whichever is greater
IBP
- Range: -50 to 300 mmHg
- Accuracy: ±2% or±1mmHg whichever is greater
EtCO2 Sidestream
- Sample Rate: 70 /100 ml/min
- Range: 0 to 99 mmHg
- awRR Range: 0 to 120 rpm
- Accuracy:
- 0 to 40 mmHg, ±2 mmHg
- 41 to 76 mmHg, ±5% of the reading
- 77 to 99 mmHg, ±10% of the reading
EtCO2 Mainstream
- Range: 0 to 150 mmHg
- awRR Range: 0 to 150rpm
- Accuracy:
- 0 to 40 mmHg, ±2 mmHg
- 41 to 70 mmHg, ±5% of the reading
- 71 to 100 mmHg, ±8% of the reading
- 101 to 150 mmHg, ±10% of the reading