MiniSim 1000 patient Simulator is a multi-parameter Patient Simulator designed for testing and verifying the performance of patient monitoring systems quickly and easily. This microprocessor based instrument is menu driven by the soft touch keypad and intuitive LCD display.
Full 12 lead ECG simulation with 14 user selectable rates from 30 to 350 BPM, and 14 user selectable amplitudes from 0.15 to 5 mV are all provided by the MiniSim 1000. Sine, Square, and Triangle performance waveforms are simulated with 14 user selectable rates from 0.1 to 100 Hz.
MiniSim 1000 also simulates 45 different arrhythmias including atrial, ventricular, tall T wave, ST elevation, ST depression, myocardial infraction, blocks, pulse, and pacer waveforms. In addition, two invasive blood pressures are simulated with choice of 12 static pressures and 6 dynamic waveforms. Respiration is simulated with 4 rates, 4 base line impedance, and 4 delta impedance selections. Apnea may be off, continuous, and with either 12 or 32 second apnea bradycardia. Finally, temperature is available at either 25° and 37° C (77° and 98.6° F).
Powered by a 9 volt alkaline battery with a typical life of 40 continuous hours, MiniSim 1000 provides unmatched choices of patient simulation in an efficient, well-designed package.
Features and Benefits
- 12 Lead ECG
- 45 Arrhythmias
- ECG Performance Waveforms
- 2 Blood Pressure Simulations
- Respiration / Apnea
- Temperature
- Easy to Use
- Small, Compact Size
- Menu Driven Operation
- Large LCD Display
- Tactile Keypad
- Battery or AC Powered
Materials Included
- MiniSim 1000 – Multi-Parameter Simulator Unit
- (10) ECG Snap to Banana Adapter
- (1) Hard Case
- (1) Non-Terminated Pressure Cable
- (1) Temperature Interface Cable
- (1) 9V Battery
- User Manual
Technical Speicifcations
- Dimensions: 5.5′ x 3.5′ x 1.5′
- ECG Specifications
- ECG Output: 12 leads with independent outputs referenced to RL. NORMAL SINUS RHYTHM (NSR)
- ECG Rates: 30, 60, 70, 80, 90, 100, 120, 150, 180, 210, 240, 270, 300, and 350 BPM. Accuracy 0.5%
- Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II. Lead 1 is 0.6 X Lead II, Lead III is 0.4 X Lead II, and Lead V is the same as Lead II
- High Level: 500 X low level output on Lead II
- Accuracy: 2% (1-5mV)
- Performance Waveforms (PERF)
- Sine, Square, Triangle, Pulse
- Frequencies: 0.1 to 0.9 in 0.1 Hz steps 1.0 to 9.0 in 1.0 Hz steps 10 to 100 in 10 Hz steps
- Accuracy: 1%
- Amplitudes: 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II
- Pulse: 20 ms pulse of 1mV amplitude repeated at 4 second intervals
- R Wave Detection
- Widths: 10, 40, 50, 60, 70, 80, 90, 100, 110, and 120 ms.
- Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mV on Lead II.
- Pacer (PCR)
- AP: Atrial Pacer set at 70 BPM
- ASP: Asynchronous Pacer
- QRS Amplitudes: 1 mV
- PCR: Pacer pulses alone
- Pacer Widths: 0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 ms
- Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV
- VP: Ventricular Pacer set at 70 BPM
- AVP: Atrial Ventricular Pacer set at 70 BPM.
- QRS Amplitude: 1 mV Pacer
- Amplitude: -2mV
- Respiration
- Baseline Impedance: 250, 500, 750, and 1000 Ohms
- Delta Impedance: 0.1, 0.5, 1.0, and 1.5 Ohms
- Accuracy: 10%
- Rates: 15, 30, 60, and 120 BPM
- Accuracy: 1%
- Apnea: Off, continuous, 12 seconds and 32 seconds
- Lead Configuration: Leads I and II
- Blood Pressure
- Impedance: 350 Ohms
- Excitation: 2 to 16 Volts
- Sensitivity: 5mV/V/mmHg Static: 0, 5, 10, 20, 25, 30, 40, 50, 100, 150, 200, and 300 mmHg
- Dynamic: 50/10, 60/20, 70/30, 80/40, 100/60, and 120/80 mmHg.
- Dynamic: waveforms track all NSR rates
- Temperature:
- Compatibility: YSI 400 and 700 Series.
- Temperature: 25° and 37° C (77° and 98.6° F)
- Accuracy: 2% of setting
Warranty Information
- 1-Year Warranty