Smiths Medical/Surgivet Advisor Tech Monitor with 3 Lead ECG, Standard SPO2, Heart Rate, NIBP, 2-Channel Temperature, 2-Channel IBP, End Tidal CO2, Respiration
$5,333.00
Smiths Medical/Surgivet Advisor Tech Monitor with 3 Lead ECG, Standard SPO2, Heart Rate, NIBP, 2-Channel Temperature, 2-Channel IBP, End Tidal CO2, Respiration. The 12-inch screen allows for easy-to-view vital signs monitoring at a glance. For your convenience, the intuitive monitors can be controlled via touchscreen, knob or hard keys, and patient vital signs data download via Wi-Fi or Ethernet for each case. Integrated printers are available on monitors including basic and advanced parameters. As your needs change, you can easily upgrade your SurgiVet Advisor tech monitor in your practice. Smith’s Medical offers multiple SurgiVet Advisor Tech Monitor configurations to meet your clinical needs.
Features and Benefit
- Standard SpO2
- 3-Lead Electrocardiogram (ECG)
- 3 modes of ECG: Monitor, Surgical, Diagnostic
- 13 Ventricular Arrhythmia Detection
- ST Elevation and Depression
- Heart Rate
- SunTech Non-Invasive Blood Pressure (NIBP)
- Apnea detection (ETCO2 Module)
- 2-channel temperature
- Drug calculator
- Impedance respiration
- Hemodynamic calculator
- Titration table
- Wi-Fi or Ethernet data download
Standard Configuration
- 3 Lead ECG
- Standard SpO2
- Heart Rate
- NIBP
- 2-Channel Temperature
- 2-Channel IBP
- End Tidal CO2
- Respiration
Materials Included
- (1) Monitor
- (1) Reflectance Sensor (V1700)
- (1) Universal “Y” Sensor (V1703)
- (1) Universal “C” Sensor (V1707)
- (1) Mini Clip (V3078)
- (1) Cuff Washing Cap (V8079)
- (1) Crocodile Clips, Pack of 3 (V2708)
- (1) Reusable Temperature Cable (WWV3418)
- (1) Lead ECG Cable (21-0460-51)
- (1) 3 Lead ECG Snap Wire (21-0461-51)
- (1) Small NIBP Cuff 3-9 cm (V8075)
- (1) Medium NIBP Cuff 5-15 cm (V8076)
- (1) Large NIBP Cuff 9-25 cm (V8077)
- (1) Extra Large NIBP Cuff 17-45 cm (V8078)
- (1) 6 Foot Hose (V8071)
- (1) Straight Sample Line with Humidifier, 10/Box (V8074)
- (1) Airway Adapter (WW1100)
- (1) TranStar Pressure Cable (MX95114)
- (1) TranStar Transducer (MX9501T)
- (1) TranStar Mounting Plate (MX800)
- (1) TranStar Pole Clamp (MX240)
- (1) Power Cord
- (1) User’s Operation Manual
Technical Specifications
- Performance
- Display: 12.1 inch color TFT
- Trace: 8 waveforms
- Waveforms: ECG (I, II, II, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBP1, IBP2, ETCO2, AG
- Indicator:
-
- Alarm indicator
- Power indicator
- QRS beep and alarm sound
- Trend time: From 30 minutes to 72 hours
- Electrocardiogram (ECG)
- Input: 5/3-lead ECG cable and standard AAMI line for connection
- Lead choice:
- 3-LeadL I, II, III
- 5-Lead: I, II, III, aVR, aVL, aVF, V
- Gain choice: x0.25, x0.5, x1.0, x2.2
- ECG Waveforms: 12 channels
- Frequency characteristic: 0.67~40 Hz (+3 dB attenuation)
- Sweep speed: 12.5, 25, 50, and 100 mm/s
- HGR display range: 0~300 bpm
- QRS detection range: High sensitivity -5 mV to 5 mV
- Accuracy: +/-1 bpm or +/-1%, whichever is greater
- Alarm limit:
- Upper limit: 80~400 bpm
- Lower limit: 20~150 bpm
- Standard SpO2
- ASpO2: Anti-motion SpO2
- SpO2 Measurement Range: 1~100%
- SpO2 Accuracy:
- 70~100%: +/-2%
-
- 0~69%: undefined
- Pulse Rate Measurement Range: 25~300 bpm
- Pulse Rate Accuracy:
- +/-2 bpm (non-motion)
- +/-3 bpm (motion)
- SpO2 Alarm Limit:
- Upper Limit: 50~99%
- Lower Limit: 50~99%
- SpO2 PR Alarm Limit:
- Upper limit: 70-320 bpm
- Lower limit: 20-150 bpm
- SpO2 probe:
- Red Light LED Wavelength: 660 +/-5 nm
- Infrared Light LED Wavelength: 940 +/- 10 nm
- Non-Invasive Blood Pressure (NIBP)
- Measuring technology: SunTech
- Measuring methodology: Automatic oscillating measurement and deflation
- Cuff inflating: <,30 s (0~300 mmHg, standard large cuff)
- Measuring period: AVE <,40 seconds
- Mode: Manual, auto, STAT
- Measuring interval in AUTO mode: 2 minutes~4 hours
- Blood pressure measuring range:
- SYS 40-265 mmHg
- DIA 20-200 mmHg
- MAP 27-222 mmHg
- Resolution: 1 mmHg
- Alarm limit:
- Horse mode
- SYS 110~160 mmHg
- DIA 90~110 mmHg
- Dog mode
- SYS 130~160 mmHg
- DUA 60~95 mmHg
- Cat mode
- SYS 120~180 mmHg
- DIA 55~100 mmHg
- NIBP pulse rate range: 25-300 bpm
- NIBP pulse rate accuracy: +/-2% or +/-3 bpm, whichever is greater
- Temperature
- Scale: Selectable °C or °F
- Channel: 2 channels
- Range:
- T1 and T2: 25°C~50°C/77°F~122°F
- Delta T: 0°C~5.5°C/32°F~41.9°F
- Accuracy:
- +/-0.2°C (25.0°C~34.9°C)/(77°F~94.8°F)
- +/-0.1°C (35.0°C~39.9°C)/(95°F~103.8°F)
- +/-0.2°C (40.0°C~44.9°C)/(104°F~112.8°F)
- +/-0.3°C (45.0°C~50.0°C)/(113°F~122°F)
- Display resolution: 0.1°C/0.2°F
- Alarm limit:
- Upper limit: 10°C~50°C/50°F~122°F
- Lower limit: 10°C~50°C/50°F~122°F
- Invasive Blood Pressure
- Measurement range: -50~300 mmHg
- Resolution: 1 mmHg
- Accuracy: +/-1 mmHg or +/-1%, whichever is greater
- Pulse rate measurement range: 30-300 bpm
- IBP pulse rate accuracy: +/-1 mmHg or +/-2%, whichever is greater
- Channel: 2 channels
- Alarm limit:
- Label : HI (mmHg) LO (mmHg)
- ART (SYS, DIA) : 0~300 0~300
- PA (SYS, DIA) : -10~120 -10~120
- CVP, LAP, RAP, ICP(MAP) : -10~140 -10~40
- CO2
- Mode of Sampling: Sidestream or Mainstream
- ETCO2 Alarm Limit:
- Upper limit: 20~100 mmHg
- Lower limit: 10~95 mmHg
- awRR Alarm Limit:
- Upper limit: 10~150 mmHg
- Lower limit: 5~100 mmHg
- Sidestream CO2 Module
- Initialization time: Capnogram displayed in less than 20 seconds, at an ambient temperature 25°C, full specifications within 2 minutes
- CO2 Measurement Range: 0~150 mmHg (0~19.7%, 0~20 kPa)
- CO2 Calculation Method: Body Temperature Pressure Saturated (BTPS)
- CO2 Resolution:
- 0~69 mmHg: 0.1 mmHg
- 70~150 mmHg: 0.25 mmHg
- CO2 Accuracy:
- 0~40 mmHg: +/- 2 mmHg
- 41~70 mmHg: +/- 5% of reading
- 71~100 mmHg: +/- 8% of reading
- 101~150 mmHg: +/- 10% of reading
- Above 80 breath per minute +/- 12% of reading
- [NOTE: Gas temperature at 25°C]
- Inspired CO2 Measurement:
- Range: 3~50 mmHg
- Method: Lowest Reading of the CO2 Waveform in the previous 20 seconds
- Selection: 20 seconds (not user-selectable)
- awRR Measurement Range: 0-150 rpm
- Mainstream CO2 Module
- CO2 Measurement Range: 0~150 mmHg (0~19.7%, 0~20 kPa) (Barometric Pressure Supplied by Host)
- CO2 Calculation Method: Body Temperature Pressure Saturated (BTPS)
- CO2 Resolution:
- 0~69 mmHg: 0.1 mmHg
- 70~150 mmHg: 0.25 mmHg
- CO2 Accuracy:
- 0~40 mmHg: +/- 2 mmHg
- 41~70 mmHg: +/- 5% of reading
- 71~100 mmHg: +/- 8% of reading
- 101~150 mmHg: +/- 10% of reading
- Above 80 breath per minute +/- 12% of reading
- [NOTE: Gas temperature at 35°C]
- Inspired CO2 Measurement:
- Range: 3~50 mmHg
- Method: Lowest Reading of the CO2 Waveform in the previous 20 seconds
- Selection: 20 seconds (not user-selectable)
- awRR Measurement Range: 0-150 rpm
- Respiration
- Measure Method: RA-LL Impedance
- Range: 0~120 rpm
- Accuracy: +/-3 rpm
- Alarm Limit:
- Upper limit: 8~120 rpm
- Lower limit: 6~100 rpm
- Sweep Speed: 6.25, 12.5 and 25 mm/s
- Networking
- Wired networking:
- Industry Standard: IEEE 802.3 wired network
- RJ45 Interface or RS232 Serial Port
- Wired networking:
- Wireless networking:
- Industry Standard: 802.11b/g wireless network
- Transmission Distance : 50 m (Visual Distance)
- Frequency Range: 2.400~,2.4835 GHz Supports TCP/IP and Wi-Fi Protocols
- Power
- Source: External AC power and internal battery
- AC Power: 100~,240 VAC, 50/60 Hz, 150 VA
- Battery: Rechargeable lithium ion battery
- Environmental
- Temperature:
- Operating : 5~40°C (41~104°F)
- Storage: -20~65°C (-4~149°F) per the IFU
- Humidity Range:
- Operating : 80%
- Storage : <,95% per IFU
- Temperature:
Warranty Information
- 1-year warranty