Sys*Stim 228 (Advanced 2-Channel, Multi-Function)

$896.00

In stock

Compare
SKU: ME228 Category:

Note: This product can only ship to a medical facility or requires a prescription.



The Sys*Stim 228 provides the flexibility to meet virtually any clinical need and has unprecedented ease of operation.

Features and Benefits

  • Choose from a broad range of waveforms, including Interferential, Pre-modulation, Medium Frequency and Biphasic with adjustable phase duration and frequency.
  • Additional versatility is provided by a selection of treatment modes that include Surge, Reciprocation, Surge with Reciprocation and Vector Rotation.
  • Two-timer mode enables two separate treatment protocols to run simultaneously.
  • Clinician can set on/off times, pulse width and frequency along with frequency modulation for some of the waveforms.
  • Easy to navigate user interface.
  • Bright color LED display.

Treatment Modes



Technical Specifications

General

  • Input: 115 VAC ±10%, 50/60 Hz, 0.4 Amp Nom.
  • Weight: 4.9 pounds
  • Dimensions: 12.0 in (L) x 8 in (W) x 7.4 in (H)
  • Operating Temperature: 50°F to 131°F (10°C to 55°C)
  • Accuracy: ±5%
  • Maximum Treatment Time: 60 minutes
  • Current Indicator Range: 0-99 mA
  • Current Indicator Accuracy: ± 2 mA

Interferential Mode

  • Waveform Type: Sinewave
  • Volts: 0–65 volts RMS, 1 Kohm load
  • Current: 0–65 mA RMS, 1 Kohm load
  • Average Current at Maximum Intensity and Frequency: 65 mA RMS
  • Maximum Current Density Under 2′ Diameter Electrode: 3.2 mA/cmІ:
  • Frequency:
    • Channel 1 = 4000 Hz
    • Channel 2 = 4000 to 4250
    • Hz variable frequency sine wave
  • Frequency Modulation:
    • 1–15 Hz
    • 80–150 Hz
    • 1–150 Hz
    • xx–xx Hz (xx=any value from 1 to 250 Hz)
  • Phase Duration: 125 µs
  • Available Amplitude Modulation Options: Vector rotation
  • Two Timer Option: No

Premodulated Mode

  • Waveform Type: Amplitude modulated sine wave
  • Volts: 0–50 volts RMS, 1 Kohm load
  • Current: 0–50 mA RMS, 1 Kohm load
  • Average current at maximum intensity and frequency: 50 mA RMS
  • Maximum current density under 2′ diameter electrode: 2.5 mA/cmІ
  • Frequency: 4,000 Hz
  • Frequency Modulation:
    • 1–15 Hz
    • 80–150 Hz
    • 1–150 Hz
    • xx–xx Hx (xx=any value from 1 to 250 Hz)
  • Phase Duration:
    • 125 µs internal sine wave
    • 4–1,000 ms beat envelope
  • Available Amplitude Modulation Options: Continuous, Surge, Reciprocation
  • Two Timer Option: Yes

Medium Frequency Mode

  • Waveform Type: Burst modulated sine wave
  • Volts: 0–50 volts RMS, 1 Kohm load
  • Current: 0–50 mA RMS, 1 Kohm load
  • Average current at maximum intensity and frequency: 50 mA RMS
  • Maximum current density under 2′ diameter electrode: 2.5 mA/cmІ
  • Frequency: 2500 Hz, Burst at 10 ms on and 10 ms off
  • Frequency Modulation: No
  • Phase Duration: 200 µs
  • Available Amplitude Modulation Options: Continuous, Surge, Reciprocation
  • Two Timer Option: Yes

Biphasic Mode

  • Waveform Type: Symmetrical biphasic square
  • wave
  • Volts: 99 volts peak, 1 Kohm load
  • Current: 0 –99 mA peak,
  • 1 Kohm load
  • Average current at
  • maximum intensity
  • and frequency: 7.2 mA
  • Maximum current
  • density under 2′
  • diameter electrode: 0.36 mA/cmІ
  • Frequency: 1–120 Hz
  • Frequency Modulation: No
  • Phase Duration: 50–300 µs
  • Available Amplitude Modulation Options: Continuous,
  • Surge,
  • Reciprocation
  • Two Timer Option: Yes

Warranty Information

  • 2-year warranty

Main Menu