LKG 601 – Basic Electrical Safety Analyzer

$496.00

In stock

Compare
SKU: 510-NTCH Categories: ,

The LKG 601, Electrical Safety Analyzer is an extremely easy to use portable Electrical Safety Analyzer designed specifically for testing non-ECG equipment. Ground resistance, leakage current, and instrument current test measurements are displayed on its large LCD.



With its unique operating features, the LKG 601 out performs all other basic analyzers. To insure accuracy, each test has calibrated test points. The accessible instrument fuse solves the maintenance problems of built-in fuses. The selectable test load provides testing flexibility. The LKG 601 meets both AMMI and IEC 601 Standards.



Features and Benefits

  • Easy to use
  • Fast, Accurate amp, Portable
  • Large LCD
  • Accessible Line Fuse
  • Selectable Test Loads
  • Calibrated Test Points
  • 15 and 20 Amp capability
  • Complies with AAMI or IEC 610-1 Test Load Loads

Measurements Performed

  • Ground Resistance
  • Case Leakage Current
  • Earth Leakage Current
  • Instrument Current Draw

Materials Included

  • LKG 601 Safety Analyzer
  • Carrying Case
  • Test Lead Cable
  • User Manual

Technical Specifications

  • Dimensions: 5.5′ x 3.25′ x 2.5′
  • Weight: 1 lbs
  • Display: 3 1/2 Digit LCD Display
  • Leakage Current: 0-1999 micro amps. All Current measurements are made through the AAMI/ANSI ESI – 1985 or IEC 601 – 1 test loads. The meter readings correspond to the true RMS value of the current.
  • Accuracy : DC to 1 kHz: +/- 1% of reading, +/- 1 LSD 1 kHz to 100 kHz: +/- 2.5% of reading +/- 1 LSD 100 kHz to 1 mHz: +/- 5% of reading +/- LSD
  • Resistance: 0 to 1999 milliohms. Accuracy is +/- 1% of reading +/- 1 LSD
  • Device Current: 0 to 19.99 amps. Accuracy is +/- 2% of FS +/- 1LSD. Measures Ground Resistance, Internal and External Leakage Current and Instrument Current.
  • Test Receptacle: Hospital Grade 110V AC – 15 amp or 220V AC 10 amp. The rocker polarity switch selects NORMAL, OFF and REVERSE Polarity to the test receptacle, and a momentary Neutral switch will open the neutral line to the test receptacle.
  • Power Requirements: 110V AC 50 – 60 Hz, 15 amps or 220V AC, 10 amps maximum rated for the test outlet and 0.1 amp rated for the unit.
  • Ambient Temperature: Operating Range: 59 to 95 degrees F (15 to 40 degrees C), Storage Temperature: 0 to 122 degree F (-20 to 60 degree C), Relative Humidity: 90% (max) at temperatures

Warranty Information

  • 1-Year Warranty